Researchers Help AI Express Uncertainty to Improve Health Monitoring Tech
For Immediate Release
A team of engineering and health researchers has developed a tool that improves the ability of electronic devices to detect when a human patient is coughing, which has applications in health monitoring. The new tool relies on an advanced artificial intelligence (AI) algorithm that helps the AI better identify uncertainty when faced with unexpected data in real-world situations.
“When AI is being trained to identify the sound of coughing, this is usually done with ‘clean’ data – there is not a lot of background noise or confusing sounds,” says Edgar Lobaton, corresponding author of a paper on the work and an associate professor of electrical and computer engineering at North Carolina State University. “But the real world is full of background noise and confusing sounds. So previous cough detection technologies often struggled with ‘false positives’ – they would say that someone was coughing even if nobody was coughing.
“We’ve developed an algorithm that helps us address this problem by allowing an AI to express uncertainty. Rather than having to decide ‘Yes, that was a cough’ or ‘No, that wasn’t a cough,’ the AI can also report that it has detected a sound it’s not familiar with. In other words, the AI is given a third option: ‘I don’t know what that was.’”
Cough detection technology is of interest for several potential health monitoring applications.
“For example, there is interest in using wearable health monitoring devices that would detect coughs in people who have asthma, which could trigger a notification about increased risk of an asthma attack,” Lobaton says. “There is also interest in using cough detection for COVID monitoring, and so on.”
However, previous cough detection technologies had high rates of false positives, with the relevant AI reporting many unfamiliar sounds as coughing. These false positives significantly limited their utility.
“In the near term, our work limits the reporting of false positives by allowing the AI to note when it hears sounds that it can’t identify,” Lobaton says. “In the longer term, our algorithm should allow us to continually train the AI, by telling it whether the unfamiliar sounds it is hearing are coughs or are unrelated noises. This should allow for much more precise detection over time.”
In addition, the researchers tested the new algorithm in computational models and found that the modified cough detection AI can operate effectively using far fewer sound samples per second than previous technologies. For example, previous cough detection tools used approximately 16,000 sound samples per second, while the new AI tool makes use of 750 sound samples per second, with similar sensitivity and fewer false positives.
“Using fewer sound samples is a significant advantage for two reasons,” Lobaton says. “First, it means that the electronic device requires less computing power – which allows us to make it smaller and more energy efficient. Second, using fewer sound samples means that the technology will not be recording understandable speech, which addresses privacy concerns.”
The researchers are currently in the process of incorporating the new algorithm into a wearable health monitoring device that can be used in real-world testing.
What’s more, the researchers say the approach they’ve taken here could be used to address a range of AI applications in which the AI is likely to encounter unexpected input that it was not trained to understand.
“We’re looking for research partners who can help us explore other health monitoring challenges that this AI modification could help address in a meaningful way,” Lobaton says.
The paper, “Robust Cough Detection with Out-of-Distribution Detection,” is published in the IEEE Journal of Biomedical and Health Informatics. First author of the paper is Yuhan Chen, a Ph.D. student at NC State. Co-authors of the paper are Pankaj Attri, a former graduate student at NC State; Jeffrey Barahona, a Ph.D. student at NC State; Alper Bozkurt, a professor of electrical and computer engineering at NC State; Michelle L. Hernandez, associate director of clinical research of the Children’s Research Institute at the University of North Carolina at Chapel Hill; and Delesha Carpenter, an associate professor in the Division of Pharmaceutical Outcomes and Policy at the University of North Carolina at Chapel Hill.
The work was done with support from the National Science Foundation (NSF) under grant number 1915599, and from NC State’s NSF-funded Advanced Self-Powered Systems of Integrated Sensors and Technologies (ASSIST) Center under grant 1160483. The mission of the ASSIST Center is to create self-powered wearables capable of long-term multi-modal sensing without having to replace or charge batteries.
-shipman-
Note to Editors: The study abstract follows.
“Robust Cough Detection with Out-of-Distribution Detection”
Authors: Yuhan Chen, Pankaj Attri, Jeffrey Barahona, Alper Bozkurt and Edgar Lobaton, North Carolina State University; Michelle L. Hernandez and Delesha Carpenter, University of North Carolina at Chapel Hill.
Published: April 5, IEEE Journal of Biomedical and Health Informatics
DOI: 10.1109/JBHI.2023.3264783
Abstract: Cough is an important defense mechanism of the respiratory system and is also a symptom of lung diseases, such as asthma. Acoustic cough detection collected by portable recording devices is a convenient way to track potential condition worsening for patients who have asthma. However, the data used in building current cough detection models are often clean, containing a limited set of sound categories, and thus perform poorly when they are exposed to a variety of real-world sounds which could be picked up by portable recording devices. The sounds that are not learned by the model are referred to as Out-of-Distribution (OOD) data. In this work, we propose two robust cough detection methods combined with an OOD detection module, that removes OOD data without sacrificing the cough detection performance of the original system. These methods include adding a learning confidence parameter and maximizing entropy loss. Our experiments show that 1) the OOD system can produce dependable In-Distribution (ID) and OOD results at a sampling rate above 750 Hz; 2) the OOD sample detection tends to perform better for larger audio window sizes; 3) the model’s overall accuracy and precision get better as the proportion of OOD samples increase in the acoustic signals; 4) a higher percentage of OOD data is needed to realize performance gains at lower sampling rates. The incorporation of OOD detection techniques improves cough detection performance by a significant margin and provides a valuable solution to real-world acoustic cough detection problems.